Damp & Mould Survey Report

Registered Building Inspector · Level 3 Fire Door Inspector · CSCS Black Card · 25 years in construction

WhatsApp / Tel: 07507 246883 · info@constructcheck.com · constructcheck.com

Report Details

ItemDetail
Report referenceCC-DM-0001 (Sample)
Property2-bed ground floor flat, [Address redacted], London
Client[Client redacted], Housing Association
Inspection typeDamp, mould & condensation root-cause survey
WeatherOvercast, 8 °C, light rain in previous 48 hours
InspectorSebastian C, Registered Building Inspector
OccupancyOccupied, tenant present

1. Executive Summary

Significant black mould growth was found in the main bedroom and bathroom. The primary cause is condensation, driven by inadequate extraction and a thermal bridge at the bedroom external wall corner. A secondary penetrating damp defect was found below the kitchen window from a failed external sill joint.

No evidence of rising damp was found. Chemical DPC injection is not required and is not recommended.
Overall hazard rating: Category 1 risk (Damp & Mould Growth, HHSRS). Action required.
RefLocationDefectSeverityPriorityPhoto
DM-01Bedroom 1, NE cornerCondensation mould, thermal bridgeMajorWithin 5 working daysPhoto 1
DM-02BathroomExtractor fan failed / undersizedMajorWithin 5 working daysPhoto 2
DM-03Kitchen, below windowPenetrating damp, failed sill sealModerateWithin 28 daysPhoto 3
DM-04Whole propertyTrickle vents closed / blockedMinorAdvise tenant & landlordPhoto 4

2. Findings

DM-01 · BEDROOM 1Major

Condensation Mould at External Corner

Observation: Black mould approx. 1.2 m² at ceiling-to-wall junction, north-east corner, extending behind wardrobe.

Readings: Surface temperature 9.1 °C vs room 18.4 °C. Relative humidity 74%. Dew point 13.7 °C, so the surface sits below dew point. Moisture meter readings at plaster surface only; deeper readings dry.

Thermal imaging: Cold band along ceiling junction consistent with missing or slumped insulation (thermal bridge).

Root cause: Condensation on a cold surface, worsened by restricted airflow behind furniture.

Recommendation: Mould wash with fungicidal treatment; inspect and make good loft or cavity insulation at junction; apply anti-condensation paint after drying; advise wardrobe set 50 mm off external wall.

Black mould at the ceiling corner of a bedroom external wall
1DM-01 bedroom corner mould
DM-02 · BATHROOMMajor

Inadequate Extraction

Observation: Mould to ceiling and silicone around bath. Extractor fan not running on test.

Readings: RH 88% 20 minutes after shower use. Fan extract rate: nil.

Root cause: Failed extractor; moisture not removed at source.

Recommendation: Replace with humidistat-controlled fan, minimum 15 l/s, with overrun timer. Clean and treat mould; reseal bath.

Failed bathroom extractor fan with mould on the surrounding ceiling
2DM-02 failed extractor fan
DM-03 · KITCHENModerate

Penetrating Damp Below Window

Observation: Tide-marked staining and blown plaster below window, approx. 600 mm wide.

Readings: High moisture readings confined to area directly below sill; readings drop to dry within 300 mm either side and at skirting level, ruling out rising damp.

External check: Open joint and cracked mastic at sill-to-frame junction; no drip groove clearance.

Root cause: Rainwater entering at failed sill joint.

Recommendation: Rake out and reseal sill joint, clear drip groove; allow wall to dry, then replaster with breathable lime-based plaster.

Cracked mastic seal at an external window sill joint
3DM-03 failed sill seal
DM-04 · VENTILATIONMinor

Trickle Vents Closed

Observation: Trickle vents closed in all rooms; two painted over.

Recommendation: Free and open all vents; provide tenant guidance leaflet on ventilation and heating.

Closed, painted-over trickle vent on a window with condensation
4DM-04 closed trickle vent

3. Hazard Assessment (HHSRS)

Damp and mould growth assessed as a Category 1 hazard, given active mould in a bedroom and bathroom, an occupied home and likely health impact. Under Awaab’s Law timescales for social landlords, works to make the home safe should be completed within 5 working days of this investigation.

4. Recommended Works Schedule

PriorityWorksRef
Urgent (5 working days)Replace bathroom extractor; mould wash and treat bedroom and bathroomDM-01, DM-02
Short term (28 days)Reseal kitchen sill; investigate and make good insulation at bedroom cornerDM-01, DM-03
Follow-upReplaster kitchen area once dry; re-inspect after 6–8 weeksDM-03
AdviceOpen trickle vents; tenant ventilation guidanceDM-04

5. Methodology & Equipment

Visual inspection internally and externally; pin and capacitance moisture meters; thermo-hygrometer for temperature, RH and dew point; thermal imaging camera; extractor flow test. Readings taken at multiple heights to distinguish condensation, penetrating and rising damp.

6. Limitations

Non-invasive survey. Areas behind fixed furniture, floor coverings and sealed voids were not opened up. Findings reflect conditions on the inspection date.

7. Independence Statement

ConstructCheck is fully independent. We do not carry out remedial works or sell damp-proofing products, so our recommendations are based only on the evidence found.

Photo Appendix

Each photo is numbered and matched to its finding reference. Photos in this sample are illustrative.

Black mould at the ceiling corner of a bedroom external wall
Photo 1Bedroom 1, NE corner: condensation mould at ceiling junction
View finding DM-01 ↑
Failed bathroom extractor fan with mould on the surrounding ceiling
Photo 2Bathroom: failed extractor, ceiling mould
View finding DM-02 ↑
Cracked mastic seal at an external window sill joint
Photo 3Kitchen window, external: cracked sill mastic
View finding DM-03 ↑
Closed, painted-over trickle vent on a window with condensation
Photo 4Window trickle vent: closed and painted over
View finding DM-04 ↑
Inspector: Sebastian C, Registered Building Inspector, ConstructCheck